Mitsubishi DX-PC3 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Oprogramowanie Mitsubishi DX-PC3. Mitsubishi DX-PC3 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - REMOTE I/O UNIT

CNCFCU6-DX561CONNECTION AND MAINTENANCE MANUALBNP-B2302*(ENG)REMOTE I/O UNIT

Strona 2 - Precautions for Safety

3. INSTALLATION 3.2 Noise Countermeasures I-4 3.2 Noise Countermeasures 3.2.1 Connection of FG (Frame Ground) The frame should basically be grou

Strona 3 - CAUTION

3. INSTALLATION 3.2 Noise Countermeasures I-5 3.2.2 Shield Clamping of Cables (1) Cables requiring ground connection with lead wire The FG wire

Strona 4 - I. CONNECTION MANUAL

3. INSTALLATION 3.2 Noise Countermeasures I-6 3.2.3 Connecting Spark Killers Connect a spark killer on the coil or contact in parallel for noise

Strona 5 - II. MAINTENANCE MANUAL

3. INSTALLATION 3.3 Installation I-7 3.3 Installation Each unit is installed in the sealed structure cabinet as a principle. When installing int

Strona 6 - I. CONNECTION MANUAL

3. INSTALLATION 3.4 Mounting Conditions I-8 3.4 Mounting Conditions (1) Parts, highly susceptible to dust, are mounted with a high density insi

Strona 7 - 1. OUTLINE

4. SYSTEM CONNECTION 4.1 General System Diagram I-9 4. SYSTEM CONNECTION 4.1 General System Diagram FGSV1CF10CF11R000MC1 MC1MC1CF11 CF10AUX2EMGB

Strona 8 - 2. CONFIGURATION

5. CONNECTION OF UNIT 5.1 Names of Each Part I-10 5. CONNECTION OF UNIT The methods for connecting to each unit and device are briefly explained

Strona 9 - Power specifications

5. CONNECTION OF UNIT 5.2 Unit Connection System Diagram I-11 5.2 Unit Connection System Diagram F010 cableCF10 RIO1↑01CS1 CS2↑CF10Remote I/O un

Strona 10 - 3.2 Noise Countermeasures

5. CONNECTION OF UNIT 5.3 Connection of Base I/O Unit I-12 5.3 Connection of Base I/O Unit The RIO1 connector is used for connection to the base

Strona 11 - CF34CF33

5. CONNECTION OF UNIT 5.4 Connection of RIO Unit I-13 5.4 Connection of RIO Unit The RIO2 connector is used to connect several remote I/O units.

Strona 12

Precautions for Safety Always read the specifications issued by the machine maker, this manual, related manuals and enclosed documents before s

Strona 13 - 3.3 Installation

5. CONNECTION OF UNIT 5.5 Connection of Power Supply I-14 5.5 Connection of Power Supply Supply the 24VDC power supply for the control circuit t

Strona 14 - 3.4 Mounting Conditions

5. CONNECTION OF UNIT 5.6 Connection of Encoder Speed Signal I-15 5.6 Connection of Encoder Speed Signal Encoder ENC1/2 (Note) Refer to follo

Strona 15 - 4. SYSTEM CONNECTION

5. CONNECTION OF UNIT 5.6 Connection of Encoder Speed Signal I-16 [Outline of connection] GNDPC∗PC1kΩ1kΩ100ΩENC1/2Spindleamplifier [Signal ass

Strona 16 - 5. CONNECTION OF UNIT

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-17 5.7 Connection of Machine Input/Output Signal Input Output Number of oc

Strona 17

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-18 [Signal assignment table] DO-LDI-LDI-RDO-LDI-LRemote I/O unitR-TMRI02 DC

Strona 18 - RIO1RIO2 DCIN

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-19 [Outline of input circuit] The digital signal input circuit includes the

Strona 19 - 5.4 Connection of RIO Unit

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-20 [Outline of output circuit] The digital signal output circuit is a source

Strona 20 - Stabilized power supply

APPENDIX 1 UNIT OUTLINE DRAWINGS AND INSTALLATION DIMENSIONS I-21APPENDIX 1 UNIT OUTLINE DRAWINGS AND INSTALLATION DIMENSIONS 0123456789ABCDEFST

Strona 21 - ENC pin No

APPENDIX 2 LIST OF CONNECTOR SETS I-22APPENDIX 2 LIST OF CONNECTOR SETS Connector case (3M) 10230-52F0-008 × 2 pcs. Strain relief

Strona 22

APPENDIX 3 CABLE MANUFACTURING DRAWINGS I-23APPENDIX 3 CABLE MANUFACTURING DRAWING As a rule, most F/R cables used with this product are

Strona 23

CAUTION 1. Items related to noise Always treat the shield cables indicated in this manual with grounding measures such as cable clamps. Sep

Strona 24 - X RX TX RX * TX RX TX RX *

APPENDIX 3 CABLE MANUFACTURING DRAWINGS I-24<Cable type name table> Appendix No. Cable type Application Max. length Standard cable lengt

Strona 25

APPENDIX 3 CABLE MANUFACTURING DRAWINGS Appendix 3.1 FCUA-R000 Cable Manufacturing Drawing I-25Appendix 3.1 FCUA-R000 Cable Manufacturing Drawin

Strona 26

APPENDIX 3 CABLE MANUFACTURING DRAWINGS Appendix 3.2 FCUA-R211 Cable Manufacturing Drawing I-26Appendix 3.2 FCUA-R211 Cable Manufacturing Drawin

Strona 27 - DIMENSIONS

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing I-27Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing

Strona 28

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.4 R300 Cable Manufacturing Drawing I-28Appendix 3.4 R300 Cable Manufacturing Drawing Applicat

Strona 29 - Soldering iron

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.5 R301 Cable Manufacturing Drawing I-29Appendix 3.5 R301 Cable Manufacturing Drawing Applicat

Strona 30

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.6 R-TM Manufacturing Drawing I-30Appendix 3.6 R-TM Manufacturing Drawing Application: Termin

Strona 31

APPENDIX 4 PRECAUTIONS FOR COMPLYING WITH UL/c-UL STANDARDS I-31APPENDIX 4 PRECAUTIONS FOR COMPLYING WITH UL/c-UL STANDARDS Observe the followi

Strona 32 - Note (3)

II. MAINTENANCE MANUAL

Strona 33 - Note (1)

1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card II-1 1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card [Block diagram] RI

Strona 34 - Note (1) (1)

FCU6-DX561 CONNECTION AND MAITENANCE MANUAL CONTENTS I. CONNECTION MANUAL 1. OUTLINE ...

Strona 35

1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card II-2 [Connector layout diagram] RIO2U:DI-RL:DI-LU:ENC2L:ENC1SW2DCINDO-LSW1PROG.PORTRIO1

Strona 36 - D-3 AM P

2. FAULT DIAGNOSIS 2.1 List of Unit LEDs II-3 2. FAULT DIAGNOSIS 2.1 List of Unit LEDs DCINENC1ENC2ST No.POWERRUNCPU-ESTOPRUNRIO ERR1 ERR2DI-RDI-

Strona 37 - STANDARDS

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-4 2.2 Troubleshooting 2.2.1 Confirmation of trouble state Confirm "when", "when doing w

Strona 38 - II. MAINTENANCE MANUAL

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-5 2.2.2 When in trouble If the system does not operate as planned or if there is any trouble in the ope

Strona 39 - 1.1 FX2N-80BMT-NC Card

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-6 (1) Problems related to the power supply The power does not turn ON. Cause Remedy The door interl

Strona 40

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-7 (2) Problems related to remote I/O unit (FCU6-DX561) If any of the following problems occur, all point

Strona 41 - 2.1 List of Unit LEDs

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-8 The operation display "RUN" LED does not turn ON. Cause Remedy The RUN/STOP switch is se

Strona 42 - 2.2 Troubleshooting

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-9 2.2.3 Behavior of independent faults The EN954-1 Category 3 machine system must be designed so that th

Strona 43 - 2.2.2 When in trouble

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.1 Maintenance Tools II-10 3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENA

Strona 44

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-11 3.2 Replacement Methods 3.2.1 Cable If the cable is re

Strona 45

II. MAINTENANCE MANUAL 1. EXPLANATION OF MODULE FUNCTIONS ... II-1 1.1 FX2N-80BMT-

Strona 46

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-12 b) For a flat cable type connector with claws, open the

Strona 47

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-13 3.2.2 Unit Usually, the unit is installed on the electr

Strona 48 - MAINTENANCE

Revision history Revision Date of revision Revision details ∗ 00/12/01 First edition issued

Strona 49 - 3.2 Replacement Methods

BNP-B2302* (ENG)REMOTE I/O UNIT・FCU6-DX561008-165(0110) MEESpecifications subject to change without notice.Printed in Japan on recycled paper.MITSUBIS

Strona 50 - (2) Pull

I. CONNECTION MANUAL

Strona 51 - 3.2.2 Unit

1. OUTLINE I-1 1. OUTLINE This manual explains the items required for installing and connecting the remote I/O unit (FCU6-DX561). The FCU6-DX561

Strona 52

2. CONFIGURATION 2.1 System Configuration I-2 2. CONFIGURATION 2.1 System Configuration 0OPENCBUS 2CBUS 1MITSU BISHIMDS-B -SVJ2Remote I/O uni

Strona 53 - REMOTE I/O UNIT・FCU6-DX561

3. INSTALLATION 3.1 General Specification I-3 3. INSTALLATION 3.1 General Specification Unit name Remote I/O unit Type name FCU6-DX561 Durin

Komentarze do niniejszej Instrukcji

Brak uwag