Mitsubishi FDT140VNV Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Klimatyzatory typu split Mitsubishi FDT140VNV. Mitsubishi FDT140VNV Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1

FDseriesInverter Packa g e d Air ConditionersHigh Performance Air Conditioning

Strona 2 - Individual ap control system

10Hig h P erfo r m ance A ir C o nd itio n in g Cool Only Wall-split System - Non InverterIndoor UnitFDTC 40/50VRCN-TC-24W-ER(Option)RC-E3(Option)O

Strona 3

11Pac k ag ed Ai r Con d i tion e rsHigh Efficiency Cool Only Wall-split System - Non InverterFDTCFDTC 40/50VRCN-TC-24W-ER(Option)RC-E3(Option)Outli

Strona 4 - Wide Operation Range

12Hig h P erfo r m ance A ir C o nd itio n in gIndoor UnitFDU71/100/125/140VReturn air optionRC-E3(Option)Wired remote controlOutline drawing (Unit:

Strona 5 - 2-core2-core

13Pac k ag ed Ai r Con d i tion e rsHigh EfficiencyFDU71/100/125/140VReturn air optionRC-E3(Option)Wired remote controlOutline drawing (Unit:mm)FDU71

Strona 6 - CnT terminal

14Indoor Unit Ducted - Medium Static PressurePoint1Adaptable Selectable static pressure and Flexible duct design with selectable air suction (direct

Strona 7 - Product line up

15Pac k ag ed Ai r Con d i tion e rsHigh EfficiencyIndoor Unitoperational dataModel FDUM50VHX-S FDUM60VHX-SRated Capacity Cool/Heat kW 5.0/5.4 5.6/6.

Strona 8 - FDT Ceiling Cassette - 4way

16Hig h P erfo r m ance A ir C o nd itio n in gIndoor Unit Ceiling SuspendedFDENRefrigeration piping can be set in three directions and the drain p

Strona 9 - 700mm Drain Pump

17Pac k ag ed Ai r Con d i tion e rsHigh EfficiencyRefrigeration piping can be set in three directions and the drain pipe arranged in two directions

Strona 10 - Installation

18Outdoor UnitWired remote control with weekly timer (option)RC-E3 stores operation data when an anomaly occurs and indicates the error on the LCD. It

Strona 11

19High Efficiency Cool Only Wall-split System - Non InverterControl System (Individual Control)Wired remote control with weekly timer (option)RC-E3 s

Strona 12 - Medium Static Pressure

Individual ap control systemCeiling Cassette -4way-Indoor unitsFDTFor the person who is far away from the indoor unitFor when one person feels hot an

Strona 13 - High Efficiency

20Hig h P erfo r m ance A ir C o nd itio n in gControl System WIRED Control (RC-E3)RC-E3 stores operation when an anomaly occurs and indicate

Strona 14 - 600mm Drain Pump

21Pac k ag ed Ai r Con d i tion e rsControl SystemOutdoor unitInternal/external CrossingIndoor unitRemote controlSL E BoardNetworkoptionsX Y X Y

Strona 15

22Hig h P erfo r m ance A ir C o nd itio n in gControl SystemOutdoor unitInternal/external CrossingIndoor unitRemote controlSL E BoardNetworkoptions

Strona 16 - ■ Ceiling Suspended

23Pac k ag ed Ai r Con d i tion e rsOther ProductsFDCKXES6 3ø 40.0 - 136.0kW• 11.2 to 136kW• 2 and 3 pipe VRF systems• Industry leading EER/COP• Redu

Strona 17

24Hig h P erfo r m ance A ir C o nd itio n in gOutdoor Unit DimensionsFDC71VN (unit:mm)SRC40ZIX-S, 50ZIX-S, 60ZIX-S (unit:mm) MarkABDEItemRefrigeran

Strona 18 - OUTDOOR UNIT (4.0-14.0kW)

25Pac k ag ed Ai r Con d i tion e rsOutdoor Unit Dimensions Outdoor Unit - 7.1 to 14.0kWFDC71VN (unit:mm)SRC40ZHX-S, 50ZHX-S, 60ZHX-S (unit:mm) Mark

Strona 19

Safety PrecautionsBefore starting useAir-conditioner usage targetThe air-conditioner described in this catalog is a dedicated cooling/heating

Strona 20 - ■ WIRED Control (RC-E3)

Individual ap control systemCeiling Cassette -4way-Indoor unitsFDTFor the person who is far away from the indoor unitFor when one person feels hot an

Strona 21 - SUPERLINK-SUPERLINK

4Hig h P erfo r m ance A ir C o nd itio n in gHigh EfficiencyQUICK CONTROL & HIGH EFFICIENCYDC PAM inverterAn inverter system has a number of ad

Strona 22

5Pac k ag ed Ai r Con d i tion e rsHigh EfficiencyNew remote control for all indoor unitsNon-polar 2 core wiring now used. Installation is easier.New

Strona 23 - Other Products

6Hig h P erfo r m ance A ir C o nd itio n in g Cool Only Wall-split System - Non InverterHigh EfficiencySize reduction and high efciency performan

Strona 24 - OUTDOOR UNIT DIMENSIONS

7Pac k ag ed Ai r Con d i tion e rs Cool Only Wall-split System - Non InverterProduct line upR410AModelCapacity Range (kW : Rated cooling capacity)2

Strona 25 - 7.1 to 14.0kW

8Hig h P erfo r m ance A ir C o nd itio n in gIndoor UnitFDT 60/71/100/125/140VOutline drawing (Unit:mm)RCN-T-36W-E(Option)RC-E3(Option)Wireless rem

Strona 26 - Before starting use

9Pac k ag ed Ai r Con d i tion e rs Cool Only Wall-split System - Non InverterFDT 60/71/100/125/140VOutline drawing (Unit:mm)RCN-T-36W-E(Option)RC-E