Mitsubishi CK-36310 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Telewizory i monitory Mitsubishi CK-36310. Mitsubishi CK-36310 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
The contents of this literature are as of Apr. 2010
This catalog is printed with soy ink.
MGS-FB-1004-EN-C
http://www.magnescale.com
Feedback Scale General Catalog
Shinagawa Intercity Tower A-18F, 2-15-1, Konan, Minato-ku, Tokyo 108-6018, JAPAN
Magnescale Co., Ltd.
Headquaters
Tokyo Office
Nagoya Office
Osaka Office
International Sales Department
Magnescale Americas Inc.
Magnescale Europe GmbH
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan
2-35-16, Meieki, Nakamura-ku, Nagoya Aichi, 450-0002, JAPAN
2-14-6, Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan
5740 Warland Drive, Cypress, CA 90630, USA
Antoniusstrasse 14, 73249 Wernau, Germany
TEL.+81 (0)463-92-1011
TEL.+81 (0)463-92-7972
TEL.+81 (0)52-587-1823
TEL.+81 (0)6-6305-3101
TEL.+81 (0)463-92-7971
TEL.+1 (949) 770-8400
TEL.
+49 (0) 7153 934 291
FAX.+81 (0)463-92-1012
FAX.+81 (0)463-92-7978
FAX.+81 (0)52-587-1848
FAX.+81 (0)6-6304-6586
FAX.+81 (0)463-92-7978
FAX.+1 (949) 770-8408
FAX.
+49 (0) 7153 934 240
:
:
:
:
:
:
:
Magnescale Co., Ltd.
Feedback scale
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - Feedback scale

The contents of this literature are as of Apr. 2010This catalog is printed with soy ink.MGS-FB-1004-EN-Chttp://www.magnescale.comFeedback Scale Genera

Strona 2 - Contents

The transport plate does not set the installation standard for the rotary magnescale. Perform the installation by following section 5-1, “Installation

Strona 3 - The advantage of scales

Installation Procedure 1. Check that there is no dust or scratches on the rotary magnescale installation surface. Check that there are no indentat

Strona 4 - Selection Guide

SR87This robust type magnetic absolute scale system that outputs position signals for machine toolsand other equipment that require high-precision pos

Strona 5 - Measurement Principle

Dimensions SR87Cable Direction RightUnit : mmDimensions SR87Cable Direction LeftUnit : mm1402403404405406407408409401040114012402783784785786787788789

Strona 6 - Figure 1 Figure 2

SR84/85This robust medium type magnetic scale systemthat outputs position signals for machine toolsand other equipment that requirehigh-precision posi

Strona 7 - Accuracy Traceability

Dimensions SR84/85Cable Direction RightDimensions SR84/85Cable Direction Left1402403404405406407408409401040114012402783784785786787788789781078117812

Strona 8 - Installation method

SR77This slim type magnetic scale systemthat outputs position signals for machine toolsand other equipment that requirehigh-precision positioning.• Me

Strona 9 - Linear Scale SR77

Dimensions SR77Cable Direction RightDimensions SR77Cable Direction Left70120170220270320370420470520570620720208258308358408458508558608658708758858L1

Strona 10

SR74/75This slim type magnetic scale systemthat outputs position signals for machine toolsand other equipment that requirehigh-precision positioning.•

Strona 11 - Mechanical Specifications

Dimensions SR74/75Cable Direction RightDimensions SR74/75Cable Direction Left7012017022027032037042047052057062072020825830835840845850855860865870875

Strona 12 - Divisions

Magnescale technology essential for high-performance machine tools Magnescale, which was developed based on Magnescale’s advanced magnetic technology,

Strona 13 - Dimensions SR87

SL110 SL13051.5/ 2.03N x 300/ 11.81P1Measuring length (L)51.5/2.03Overall length : L + 103/ 4.0610.5/ 0.419/ 0.3510.5/0.41Clamp(included)4.1/0.161 x 6

Strona 14

Integrated reader head and Interpolator unit for position controlPLPL81/PL82• Compact design• Interpolator unit for automated position control• High r

Strona 15 - Dimensions SR84/85

Head cable unitPLPL101 Series• Non-contact detection• Magnetic detection system for excellent resistance to dust, oil, vibrations and shocks.• Dete

Strona 16

Digital ScalesRotary scaleRU77RS31044 45

Strona 17 - Dimensions SR77

RU77High precision absolute rotary type with exellent resistance to environments.• System accuracy : ± 2.5sec• Output wave number : 212 = 4,096• Ou

Strona 18

MJ100/110MJ620MJ820/821MJ830/831InterpolatorsRotary scale for feedback applicationsRSRS310• Magnetic principle• Excellent resistance to workshop condi

Strona 19 - Dimensions SR74/75

Compact one-axis module with analog input portMJMJ620• Divides analog input signal into 32 to 800 divisions.• Produces AB quadrature signal output fro

Strona 20 - SL110/SL130

Interpolator for Mitsubishi MR-J2 Super Series amplifierMJMJ830/831• Connectable to any general analog-output encoder. Input impedance: 120 Ω 1 Vp-

Strona 21 - PL20C/PL25

ContourProtocol Standard Mitsubishi FanucModelCH33-**○▽CH33-**○▽ZACH33-**○▽LCH33-**○▽LACH33-**○▽MCH33-**○▽MACH33-**○▽E/PCH33-**○▽EA/P

Strona 22 - Specifications

The total quality control system that operates throughout the entire design and production process ensures products with enhanced safety, high quality

Strona 23 - Digital Scales

What is Magnescale?A scale is mainly used for machine tools and detects theposition of a component such as the stage to which it is installed.Feeding

Strona 24 - RU77-4096A

http://www.mgscale.com58 59

Strona 25 - Interpolators

Selection GuideAccuracy3+3ML/1,000μmp-p5+5ML/1,000μmp-p3+3ML/1,000μmp-p5+5ML/1,000μmp-pMeasurement length(ML: mm)70mm-2,040mm140mm-3,040mmTypeSR77SR75

Strona 26 - MJ100/110

Figure 1 Arrangement of MR element and magnetic mediaHXISNMR element (X)Figure 2 Structure of high-precision MagnescaleMetal base Magnetic mediaMR e

Strona 27 - MJ820/821

000100 1101λIncrementalsignalM code00010010Incremental signal detection Absolute signal detection Sin Cosbit1 2 3 4...Output signal- Wavelength: 40, 8

Strona 28 - List of Adopter Cables

The He-Ne stabilized laser, the standard for accuracy measurement, is frequency calibrated in-house using the “633-nm iodine molecular absorption line

Strona 29 - Connection Cable

3. Bring the scale into contact with the stop surfaces and install.Installation exampleScale installation accuracy is improved when a stop surface

Strona 30

Air injection and oil lubrication In the standard configuration, the end cap section is provided with an M5 tap hole for air injection and oil lubric

Komentarze do niniejszej Instrukcji

Brak uwag