Mitsubishi MIM-A01 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Mitsubishi MIM-A01. Mitsubishi MIM-A01 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 62
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Mitsubishi MIM series
Industrial Modems
Instructions Manual
MIM-G01
MIM-A01
INDUSTRIAL AUTOMATION
MIT
SU
BI
S
HI ELE
C
TRI
C
Art.-No.: 165584
27 10 2005
Version A
MIT
SU
BI
S
HI ELE
C
TRI
C
Draft
Przeglądanie stron 0
1 2 3 4 5 6 ... 61 62

Podsumowanie treści

Strona 1 - Mitsubishi MIM series

Mitsubishi MIM seriesIndustrial ModemsInstructions ManualMIM-G01MIM-A01INDUSTRIAL AUTOMATIONMITSUBISHI ELECTRICArt.-No.: 16558427 10 2005Version AMITS

Strona 2

ContentsVI MITSUBISHI ELECTRIC6 Configuration6.1 MIM and Mitsubishi ALPHA XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 3 - About this Manual

1 Mitsubishi Industrial Modems at a glance1.1 Mitsubishi Normal Modem GSM (MIM-G01)The Mitsubishi Normal Modem GSM is a generic modem for industrial u

Strona 4

2 Equipment Versions2.1 Modem TypThe Mitsubishi Normal Modem GSM requires, like any conventional modem, a software in thePC like a program for dial-up

Strona 5 - Art-No.: 165584

3 Mounting and Installation3.1 Normal Modem GSM (MIM-G01)The MIM-G01 is a GSM/GPRS mobile modem intended for transmission of data, SMS, e-mailand fax

Strona 6 - II MITSUBISHI ELECTRIC

3.1.2 Meaning of the LEDsThe MIM-G01 presents two LEDs, which indicate the devices current operating mode. After thepower supply has been switched on,

Strona 7 - Security Advice

3.1.3 Connecting the GSM antennaFirst of all find a suitable location for mounting the GSM antenna outside of the control cabinet.Screw the antenna pl

Strona 8 - IV MITSUBISHI ELECTRIC

NOTE If you plan to dial into your PLC via GSM, you will possibly need a SIM card and account withdata service enabled. However, in some cases the mod

Strona 9

3.2 Super Modem 56k (MIM-A01)The MIM-A01 is a PSTN modem intended for transmission of data, SMS, e-mail and fax mes-sages by analog telephone networks

Strona 10

3.2.2 Meaning of the LEDsThe MIM-A01 got five LEDs, which display the modems operating status. After the power supplyhas been switched on, a self test

Strona 11

3.2.3 Connection to the Telephone NetworkConnection to telephone network (PSTN) is established via the included telephone cable andthe "Line"

Strona 13 - 3 Mounting and Installation

3.3 MountingMount the modem by pushing or snap fitting it onto a DIN rail (top-hat rail 35 mm).EATTENTION:PDANGER:Mounting Mounting and Installation3-

Strona 14 - 3.1.2 Meaning of the LEDs

4 Power supplyAfter all installation steps are completed, switch on the power supply to the Mitsubishi AlarmModem. The modem got two power supply conn

Strona 15 - 3.1.4 Inserting the SIM card

5 OperationIf you have followed the steps in the chapters 3 and 4, your modem is ready for operation.5.1 MIM-G01The MIM-G01 presents two LEDs, which i

Strona 16 - SIM-Card

6 Configuration6.1 MIM and Mitsubishi ALPHA XLConfiguration of the Industrial Modems is done via the Mitsubishi Alpha Programming Software(SW0D5-ALVLS

Strona 17 - 3.2 Super Modem 56k (MIM-A01)

6.1.2 Function Block SMS sendFor sending SMS, add a function block GSM/SMS is to be added to your PLC project.(Detailed information is to be found wit

Strona 18 - 3.2.2 Meaning of the LEDs

Recipient:Enter several recipients with name and number here. Enable the Mobile Phone button for SMSand Gateway for e-mail.Click on OK to return to th

Strona 19 - Fig. 3-8

6.1.3 PLC ConnectionConnect the RS232 jack to the ALPHA XL, using the GSM-CAB. If done so, plug the powersupply into the appropriate terminal.NOTE Mak

Strona 20 - 3.3 Mounting

6.2 MIM and Mitsubishi MELSEC FXThe modem may be operated along with MELSEC FX in two ways: As GSM modem for "FXMessenger" or as modem for F

Strona 21 - 4 Power supply

6.4 RS 232-Transparent-Mode (TransMode)The section is only valid for the Mitsubishi Super Modem (MIM-A01).The TransMode allows the remote control of a

Strona 22 - 5 Operation

6.4.2 TransMode Command6.4.3 TransMode Login CommandTo use the TransMode of the Mitsubishi Super Modem, these prerequisites must be met쎲The Mitsubishi

Strona 23 - 6 Configuration

About this ManualThe texts, illustrations, diagrams and examples in this manual are onlyintended as aids to help explain the functioning, operation, u

Strona 24 - 6.1.2 Function Block SMS send

Login without parameters[password] Login with password[ ] Login without passwordLogin with password and parameters[password; Format:format; Handshake:

Strona 25 - Fig. 6-4:

7 Technical DataMain FeaturesSystem ArchitectureTelephone- /GSM NetworkTechnical DataMitsubishi Industrial Modem 7-1Features MIM-G01 MIM-A01Fax Via Fa

Strona 26 - 6.1.3 PLC Connection

FirmwareGeneral DataTechnical Data7-2 MITSUBISHI ELECTRICFeatures MIM-G01 MIM-A01Operating System —Commercial RTOS (real-time multitaskingoperating sy

Strona 27

7.1 Dimensions7.1.1 MIM-G01Technical Data DimensionsMitsubishi Industrial Modem 7-3Push-+RS 23288Antenna10...40 V DCPowerStatus GSMNGSMORMAL MODEMNORM

Strona 28

7.1.2 MIM-A01Dimensions Technical Data7-4 MITSUBISHI ELECTRICCOM1(RS232)-+DC 10...30V88ServicePowerLineMail inModem ModeMail outSUPER MODEM56kSUPER MO

Strona 29 - 6.4.3 TransMode Login Command

8 Appendix8.1 AT Commands MIM-G01This chapter describes the most important MIM-G01 AT modem commands. Detailed informa-tion on these may be obtained f

Strona 30 - RS232Speed]

+CNUM – Own NumberThis Command sets the own number (MSISDN) of the SIM card for any service.Defined parameters:<alphax> name for the number <

Strona 31 - 7 Technical Data

+ICF–DataFormatThis Command sets data format of serial interface.Defined parameters:<format> <parity> <format> <parity>1: 8 Da

Strona 32 - Tab. 7-5: General Data

+COPS – GSM NetworkThis command requests accessible networks and sets the GSM home network.Defined parameters:<mode> <format>:0: automatic

Strona 33 - 7.1 Dimensions

8.1.2 Overview of AT-CommandsService CommandsV24-V35 CommandsAppendix AT Commands MIM-G01Mitsubishi Industrial Modem 8-5Command Description+CLIR Calli

Strona 35 - 8 Appendix

Dial CommandsGeneral CommandsNetworkSecurityAT Commands MIM-G01 Appendix8-6 MITSUBISHI ELECTRICCommand DescriptionD Dial commandH Hang-up CommandA Ans

Strona 36 - Tab. 8-5: +IPR – Baudrate

PhonebookSMS CommandsData CommandsAppendix AT Commands MIM-G01Mitsubishi Industrial Modem 8-7Command Description+CPBS Select Phone Book Memory+CPBR Re

Strona 37 - Tab. 8-7: +IFC – Flow Control

Fax Commands CLASS1Fax Commands CLASS2Special AT CommandsAT Commands MIM-G01 Appendix8-8 MITSUBISHI ELECTRICCommand Description+FTM Transmit Speed+FRM

Strona 38 - Tab. 8-9: +CMGS – Send SMS

8.2 AT Commands MIM-A018.2.1 Overview of AT CommandsCommands can be entered alone or in strings, and they must be preceded - except the A/ com-mand -

Strona 39 - 8.1.2 Overview of AT-Commands

8.2.2 AT Command DescriptionsThis chapter describes the most important AT commands of the modem. The values markedwith an asterisk (*) are the default

Strona 40 - Tab. 8-15: Security

D - Dial CommandThis command causes the modem to immediately go off-hook as an originating modem and diala telephone number with corresponding dial mo

Strona 41 - Tab. 8-18: Data Commands

&W - Store Active ProfileThis command causes the modem to store a subset of the active profile command and S-regis-ter configurations into the NVR

Strona 42 - 8-8 MITSUBISHI ELECTRIC

8.2.4 Message CommandsIn Message Mode, you can send this extended command set to the modem.If you use this command in Modem Mode, an error will occur.

Strona 43 - 8.2 AT Commands MIM-A01

8.2.5 AT+T Send - Sending SMS, E-Mail, Fax and Express E-Mail MessagesSetting General Message ParametersSending a FaxAT Commands MIM-A01 Appendix8-14

Strona 44 - 8.2.2 AT Command Descriptions

Sending an SMS MessageAppendix AT Commands MIM-A01Mitsubishi Industrial Modem 8-15AT+T Send="SMS;..."AT+T Send="SMS; To: recipient; Ser

Strona 45

Mitsubishi Industrial Modem iInstruction ManualIndustrial Modems MIM-A01 and MIM-G0Art-No.: 165584Version Changes / Additions / CorrectionsA 10/2005 p

Strona 46 - 8.2.3 Overview of S-Registers

Sending an Express E-MailAT Commands MIM-A01 Appendix8-16 MITSUBISHI ELECTRICAT+T Send="Express;..."AT+T Send="Express; To: Recipient;

Strona 47 - 8.2.4 Message Commands

Sending Internet E-Mail (SMTP)Appendix AT Commands MIM-A01Mitsubishi Industrial Modem 8-17AT+T Send="Email;..."AT+T Send="Email; To: Re

Strona 48 - Short modem reply:

Retrieving Internet E-Mail (POP3)AT Commands MIM-A01 Appendix8-18 MITSUBISHI ELECTRICAT+T Send="POP3;..."AT+T Send="POP3; Dial: Number;

Strona 49 - Comprehensive modem reply:

8.2.6 Message CommandsAT+TList - Displaying Received MessagesAT+T Delete - Deleting a Stored MessageAppendix AT Commands MIM-A01Mitsubishi Industrial

Strona 50

AT+T Read - Reading a Stored MessageAT Commands MIM-A01 Appendix8-20 MITSUBISHI ELECTRICAT+T Read=Number..Lists the message with the indicated ID from

Strona 51

8.2.7 Modem CommandsAT+T Answer - Setting the Response BehaviourAT+T Time - Setting the System TimeAppendix AT Commands MIM-A01Mitsubishi Industrial M

Strona 52 - Modem reply:

Reading the Current System TimeAT+T Echo - Switching the Echo On or OffAT+T Verbose - Switching Comprehensive Responses On or OffAT Commands MIM-A01 A

Strona 53

AT+T Mode - Activating Modem Mode or Message ModeAT+T Help - Showing a Command OverviewAT+T Erase - Resetting the ModemAT+T RedialAppendix AT Commands

Strona 54 - Comprehensive response

AT+T RedialDelayAT+T DialRules - Dial Method, Dial Tone DetectionAT Commands MIM-A01 Appendix8-24 MITSUBISHI ELECTRICAT+T RedialDelaySets the time to

Strona 55

AT+ T Speaker - Adjusting the Modem Speaker VolumeAppendix AT Commands MIM-A01Mitsubishi Industrial Modem 8-25AT+T Speaker="Volume"Sets the

Strona 56

II MITSUBISHI ELECTRIC

Strona 57

Indexi Mitsubishi Industrial ModemIndexAAntennacable· · · · · · · · · · · · · · · · · · · · · 3-5connecting · · · · · · · ·

Strona 59

MITSUBISHI ELECTRICHEADQUARTERSMITSUBISHI ELECTRIC EUROPEEUROPE B.V.German BranchGothaer Straße 8D-40880 RatingenPhone: +49 (0) 2102 / 486-0Fax: +49 (

Strona 60

Security AdviceIntended Target AudienceThis manual is aimed exclusively at suitably qualified electrical engineering specialists that arefamiliar with

Strona 61

IV MITSUBISHI ELECTRIC

Strona 62 - INDUSTRIAL AUTOMATION

ContentsMitsubishi Industrial Modem V1 Mitsubishi Industrial Modems at a glance1.1 Mitsubishi Normal Modem GSM (MIM-G01) . . . . . . . . . . . . . . .

Komentarze do niniejszej Instrukcji

Brak uwag