6 POSITIONING CONTROL
6.4 3 Axes Linear Interpolation Control
Linear interpolation control from the current stop position with the specified 3 axes is
executed.
Items set using MT Developer
Common Arc Parameter block Others
Servo
instruction
Positioning
method
Number of
control axes
Parameter block No.
Axis
Address/travel value
Command s
p
eed
Dwell time
M-code
Tor
q
ue limit value
Auxiliar
y
p
oint
Radius
Central
p
oint
Control unit
S
p
eed limit value
Acceleration time
Deceleration time
Ra
p
id sto
p
deceleration time
Tor
q
ue limit value
Deceleration
p
rocessin
g
on sto
p
in
p
ut
Allowable error ran
g
e for circular inter
p
olation
S-curve ratio
Cancel
WAIT-ON/OFF
Speed change
ABS-3
Absolute
INC-3
Incremental
3
Valid
: Must be set
: Set if required