Mitsubishi MOTION CONTROLLERS Q172DCPU Instrukcja Obsługi Strona 176

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 448
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 175
6 - 37
6 POSITIONING CONTROL
(6) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
4 axes linear interpolation control
Axis used . . . . . . . Axis 1
, Axis 2, Axis 3, Axis 4
Command positioning speed
Vector speed . . . . . . . . . . . . . . . 10000[PLS/s]
SET M2042
INC-4
Axis 1, 3000PLS
Axis 2, 4000PLS
Axis 3, 4000PLS
Axis 4, 4000PLS
Speed 10000PLS/s
PX000*M2415*M2435*M2455
END
!PX000
4 axes linear interpolation control
4 axes linear
Wait until PX000 turn off after linear interpolation
completion.
Turn on all axes servo ON command.
Wait until PX000, Axis 1 servo ready, Axis 2 servo ready,
Axis 3 servo ready and Axis 4 servo ready turn on.
. . . . . . .
Axis 1 . . . 3000[PLS]
Axis 2 . . . 4000[PLS]
Axis 3 . . . 4000[PLS]
Axis 4 . . . 4000[PLS]
Travel value to
stop position
*M2475
interpolation control
[F10]
[G10]
[K22]
[G20]
(Note): Example of the above Motion SFC program is started using the automatic start or PLC program.