Project creation Sample project creation with MT Developer2 and GX Developer
5 - 6
Motion SFC Program Creation
In the "Project Window Menu" under "Motion SFC Program", double-click Motion SFC Program
Manager. This open the "Motion SFC Program Manager" pop-up window.
Click the icon New which opens up the "New Motion SFC Program" window. Set the Motion SFC
Program No. to "1", enter "1 Axis JOG" as the program name and then click OK.
In the "Project Window Menu" under “Motion SFC Program”, double-click Motion SFC Parameter.
This open the “Motion SFC Parameter” pop-up window.
Double-click program 1 and then change the Start Setting to "Automatic Start".
Then close this window.