4 - 3
4 INSTALLATION AND WIRING
4.1.2 Instructions for mounting the base unit
When mounting the Motion controller to an enclosure or similar, fully consider its
operability, maintainability and environmental resistance.
(1) Fitting dimensions
Fitting dimensions of each base unit are as follows:
I/O11
W
Hs
H
OUT
FG
SG
5V
I/O1 1
I/O10
I/O9I/O8
I/O6
I/O5
I/O4I/O3I/O2I/O1
I/O0CPU
POWER
I/O7
Ws
2
Ws
Q312DB
3
Ws1
2
Hs
1
5-fixing screw (M4 14)
Q38DB Q312DB Q63B Q65B Q68B Q612B
W 328 (12.91) 439 (17.28) 189 (7.44) 245 (9.65) 328 (12.91) 439 (17.28)
Ws1 15.5 (0.61)
Ws2
170 ± 0.3
(6.69 ± 0.01)
170 ± 0.3
(6.69 ± 0.01)
190 ± 0.3
(7.48 ± 0.01)
190 ± 0.3
(7.48 ± 0.01)
Ws3
138 ± 0.3
(5.43 ± 0.01)
249 ± 0.3
(9.80 ± 0.01)
167 ± 0.3
(6.57 ± 0.01)
222.5 ± 0.3
(8.76 ± 0.01)
116 ± 0.3
(4.57 ± 0.01)
227 ± 0.3
(8.93 ± 0.01)
H 98 (3.86)
Hs1 7 (0.28)
Hs2 80 ± 0.3 (3.15 ± 0.01)
[Unit: mm (inch)]