7.44
Bimba Digital Panel Meter
DPM Specifications
1. DISPLAY: 5 digit, 0.56" red LED, (-19999 to 99999)
2. POWER: 85 to 250 VAC, 50/60 Hz, 15 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs.
3. ANNUNCIATORS:
MAX - max readout selected
MIN - min. readout selected
TOT - totalizer readout selected, flashes when total overflows
SP1 - setpoint alarm 1 is active
SP2 - setpoint alarm 2 is active
SP3 - setpoint alarm 3 is active
SP4 - setpoint alarm 4 is active
Units Label - software controlled units label backlight
4. KEYPAD: 3 programmable function keys, 5 keys total
5. A/D CONVERTER: 16 bit resolution
6. UPDATE RATES:
A/D conversion rate: 20/readings sec
Step response: 200 msec. max. to within 99% of final read-
out value (digital filter and internal zero correction disabled)
700 msec. max. (digital filter disabled, internal zero correction
enabled).
The meter periodically (every 12 seconds) imposes a 500
msec delay to compensate for internal zero drift. If the delay
affects applications where step response is critical, it can be
defeated. Set the display update to 20/sec to disable. In this
case, add a zero error of 0.1% FS over the 0 to 50°C range.
Display update rate: 1 to 20 updates/sec
Setpoint output on/off delay time: 0 to 3275 sec
Analog output update rate: 0 to 10 sec
Max./Min. capture delay time: 0 to 3275 sec
7. RANGE OVERLOAD RESPONSE:
Display flashes [OLOL] at approximately 105% above range
Display flashes [ULUL] at approximately -5% below range
8. DPM PFC INPUT:
* After 20 minute warm-up. Accuracy is specified in two ways:
Accuracy over an 18 to 28°C and 10 to 75% RH environment;
and accuracy over a 0 to 50°C and 0 to 85%RH (non-condensing
environment). Accuracy over the 0 to 50°C range includes the
temperature coefficient effect of the meter.
9. EXCITATION POWER:
9V ±4% initial value regulated, 130 mA max.
10. LOW FREQUENCY NOISE REJECTION:
Normal Mode: > 60 dB @ 50 or 60 Hz ±1%, digital filter off
Common Mode: > 100 dB, DC to 120 Hz
11. USER INPUTS (Logic Level): Three software defined user
inputs, jumper selectable for sink/source logic
Max. Continuous Input: 30 VDC
SINKING INPUTS (DEFAULT) SOURCING INPUTS
INPUT STATE 22 KWpull-up to +5 V 22 KWpull-down
Active
V
IN < 0.7 VDC
V
IN
> 2.5 VDC
Inactive
V
IN
> 2.5 VDC
V
IN < 0.7 VDC
Isolation To Sensor Input Common: Not isolated
12. TOTALIZER:
Time Base: second, minute, hour, or day
Time Accuracy: 0.01% typical
Decimal Point: 0 to 0.0000
Scale Factor: 0.001 to 65.000
Low Signal Cut-out: -19,999 to 99,999
Total: 9 digits, display alternates between high order and low
order readouts
13. CUSTOM LINEARIZATION:
Data Point Pairs: Selectable from 2 to 16
Display Range: -19,999 to 99,999
Decimal Point: 0 to 0.0000
14. SERIAL COMMUNICATIONS: (RS232 or RS485)
Isolation To Sensor & User Input Commons:
500 Vrms for 1 min.
Working Voltage: 50 V
Not Isolated from all other commons.
Data: 7/8 bits
Baud: 300 to 19200
Parity: no, odd or even
Bus Address: selectable 0 to 99, Max. 32 meters per line
(RS485)
Transmit Delay: selectable for 2 to 50 msec or 50 to 100
msec (RS485)
15. ANALOG OUTPUT:
Types: 0 to 20 mA, 4 to 20 mA or 0 to 10 VDC
Isolation To Sensor & User Input Commons: 500 Vrms for
1 min.
Working Voltage: 50 V
Not Isolated from all other commons.
Accuracy: 0.17% of FS (18 to 28˚C); 0.4% of FS (0 to 50˚C)
Resolution: 1/3500
Compliance: 10 VDC: 10 KW load min.
20 mA: 500 W load max.
16. Quad Sourcing Open Collector:
(Standard with DPM):
Type: Four isolated sourcing PNP
transistors.
Isolation To Sensor & User Input
Commons: 500 Vrms for 1 min.
Working Voltage: 50 V
Not Isolated from all other commons.
Rating: Internal supply: 24 VDC ± 10%,
30 mA max. total all four outputs.
External supply: 30 VDC max., 100 mA
max. each output.
QUAD SOURCING
OUTPUT FIELD
TERMINALS
-
EXTERNAL
SUPPLY
- 01 SRC.
- 02 SRC.
- 03 SRC.
- 04 SRC.
- COMMON
20
21
22
23
24
25
Accuracy*
(18 to 28C)
Accuracy*
(0 to 50C)
Impedance/
Compliance
Max
Continuous
Overload
Resolution
0.03% of
reading ± 3 mV
0.12% of
reading + 4mV
1.066 Mohm 300 V 1mV
ISOLATION
SOURCE
OUT
COMM.
+24V
EXTERNAL
SUPPLY
(30 V MAX.)
SINK OUT
Przeglądanie stron 43