7.50
Bimba Electronic Controller
Electronic Controller Specifications
Position Feedback Control Module
Unless noted otherwise:
Ambient Temperature = (25°C) 77°F Nominal
Aux Power (AC Models) = 120 VAC, 60 HZ
Aux Power (DC Models) = 24 VDC
Relay Outputs
Control Limit Set Point Range .......... 2 independent adjustments settable
from 0 to 100% of cylinder stroke
Temperature Influence on Control Limits ................... ±0.01% stroke /°C
(-30°C to +70°C)
Output Contact Ratings ..... 5 A, 250 VAC, 0.8 power factor (general use)
5 A, 30 VDC (resistive)
360 VA, 240V, 0.4 power factor (Pilot Duty)
Output Contact Configuration ..........2 independent form C (SPDT) relays
Each relay has a corresponding control limit set point adjustment
Response Time (Excluding Bounce)
Operate Time = 8 mS TYP/12 mS maximum
Release Time = 4mS TYP/6 mS maximum
Mechanical Life ......................................20,000,000 operations minimum
Analog Outputs
Output Load Specifications ....................0 to 10 VDC @ 10 mA maximum
4 to 20 mA @ 500 W maximum loop resistance
350 W for 12 VDC input
Zero Offset Adjustment Range ................................. ±5V (10 VDC output)
±8mA (4 to 20 mA output)
Gain Adjustment Range .......................From 0.5 to 2.0 times input signal
Output Limits ................................................. 13v typical (10 VDC output)
25mA typical (4 to 20 mA output)
Temperature Influence on Analog Output .....<±0.02% Full Scale Output /°C
(-30°C to +70°C)
Output Ripple .................................................<0.2% of Full Scale Output
Response Time (0 to 90% of final value)
0 to 10 VDC = 2mS TYP/3 mS maximum
4 to 20 mA = 2 mS TYP/3 mS maximum
Komentarze do niniejszej Instrukcji