7.46
Bimba Digital Panel Meter
Basic Connections
Wires 6" Leads Plug
Input Red Blue
Ground Black Black
Output White Brown
Wire Colors
Note: Option card
field connections
are supplied with
the card.
Custom Units Overlay
The meter has a backlighted units indicator that can be custom-
ized to the application. The backlight is turned on by program-
ming the “b-Llt” parameter. Overlays are available in the Units
Label Kit. To install an overlay, remove the unit from the case.
Select the label and apply it to the label frame, noting that the
label must be aligned accurately. Install the label frame to the
display board in the alignment holes located on the right side of
the display.
Plug-In Cards
The meter has three plug-in card slots. Each slot is dedicated to
a specific function. These functions are:
• Setpoint Outputs • Analog Outputs • Communication
Option
The plug-in cards can be used in any combination, however, it is
only possible to use one type of card from each category. Cards
can be installed initially, or at a later date as system needs arise.
Devicenet Plug-In Card
A DeviceNet communication port can be added to the
meter. DeviceNet is a high level bus protocol based upon
the CAN specification. The protocol allows the integration
of devices of different types and manufacturers within a
common communication framework.
Analog Output Plug-In Card
The analog output is available as a Plug-in card. Either
the 20 mA or the 10 V output can be used. The output
can be scaled independent of the input range. Reverse
acting output is possible by reversing the scaling point
positions. Other features are selectable update rate and
output source selection.
RS485 Plug-In Card
An RS485 communication port can be added with a
Plug-in card. RS485 offers multi-drop bus communica-
tions. All devices connect in parallel on a 485 bus. Only
one device is permitted to transmit at any one time, while
all other devices are in receive mode. The meter controls
the bus when it transmits data, otherwise the meter is in
the receive mode.
RS232 Plug-In Card
An RS232 communication port can be installed with a
Plug-in card. RS232 is intended to allow only 2 devices
to communicate to each other (i.e., printer or computer).
For more information, See DPM Serial Application Guide.
Inputs
Voltage Inputs
The Bimba PFC uses the ±20V range (default).
Scaling
The meter has been factory calibrated on all ranges as a basic
multimeter (voltmeter/ammeter/ohmmeter). The basic meter
readout can then be post scaled to read out in the process units
(level, flow, temperature, etc.). The meter provides two ways in
which to scale the display:
Key-in: Key in the input and display scaling points using known
data.
Apply: Apply the actual input value and key in the corresponding
display value. The meter records the input value applied.
For processes that require linearity compensation, up to 16
scaling points can be used for correction. The scaling range is
extended up to five digits of resolution with selectable display
rounding factors.
Input Features
A unique adaptive input filter is used. Whenever the difference
between one reading and the next is less than the filter band
value, the input is filtered. When the difference exceeds the filter
band value, the input is not filtered. This avoids the usual com-
promise between using a relative high time constant for good
noise rejection and using a low time constant filter for quick step
response.
The readout can be corrected for process zero errors with an
offset value. A tare function zeros the readout via a function
operation.
Function Keys and User Inputs
The Function Keys and User inputs can be programmed to
perform specific meter control operations. Function Keys #1 and
#2 each have two types of functions, primary and secondary.
The primary function is executed the instant the key is pressed.
Holding the key for three seconds executes the second function.
If the key is not held for 3 seconds, the second function is not
executed. To implement a hidden key, program no function for
the primary and program the desired function for the second.
The three user inputs can be selected for sinking or sourcing
logic.
Max and Min Reading Detection
The meter records the maximum (max) and minimum (min) pro-
cess inputs. Conditions such as value activation, sudden change
in material flow rate, etc., can result in false peaks which are not
reflective of the true maximum and minimum of the process. In
this case, Max and Min capture delay times can be used to pre-
vent the detection of false maximums and minimums.