Przeglądanie stron 118
Test 10
10-1
FX
2N
-1RM-E-SET Programmable Cam Switch
10. Test
This section describes the procedure to modify the set data while the FX
2N
-1RM is in the RUN
mode.
10.1 Operating procedure of the test mode
The set data in a program can be modified in the test mode even if the FX
2N
-1RM is in the RUN
mode. However, a program cannot be added or deleted.
The set data can be modified in the increment of 0.5 degree using the [+] and [-] keys.
(Operations are in accordance with the resolution selected.) Numerics cannot be entered.
< Key operation >
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
< Display >
BANK: Displays the bank No. monitored.
OUT: Displays "00".
STEP: Displays "0".
DEG: Displays the existing set value.
ON LED: Lit.
RUN LED: Lit.
BANK
Changing over to the test mode
GO
Press these keys at the same
time.
+
After executing a bank whose data is to be modified, change over to the test mode using the following procedure.
BANK
Executed
bank No.
OUT
"0" is
displayed
STEP
"0" is
displayed
DEG
Set value
is
displayed
ON LED
Lit
RUN LED
Lit
< Key operation >
0OUT
Selecting an output No/step No. to be modified
Select the output No.
GO
0STEP GO
Select the step No.
+ -
Display the ON/OFF angle to be modified using the [+] and [-] keys.
If an output No. for which a program is not present is specified, the error code "E15" is
displayed.
When an output No. for which a fixed output pattern automatically generated by FNC70
to FNC75 is selected, the error code "E01" is displayed.