BFM Assignment 7
7-1
FX
2N
-1RM-E-SET Programmable Cam Switch
7. BFM Assignment
This section describes the buffer memory (BFM) of the FX
2N
-1RM.
When the FX
2N
Series PLC is connected to the FX
2N
-1RM, data can be read/written from/to the
BFM by FROM/TO instructions. (Refer to Paragraph 7.3.)
When two or three FX
2N
-1RM units are connected, FROM/TO instructions are available in only
the unit nearest to the PLC main unit.
The second and third FX
2N
-1RM units can write and read data from the PLC main unit via the
first FX
2N
-1RM unit.
7.1 BFM list
BFM No. Name
Initial
value
Remarks R: For read W: For write
K: Keep
File register
assignment No.
#0 Initial setting 0
⎯
W, K D7144
#1 Reference angle (ADJ) 0
×
1 value (1 degree),
×
2 value (0.5 degree)
Refer to Paragraph 6.5.
W, K D7145
#2
#8002
#9002 *1
Bank No. specification (00 to 07) 0
Valid when bank specification
is set to PLC.
W
⎯
#3
#8003
#9003 *1
Command 0
⎯
W
⎯
#4 Output prohibition (Y00 to Y17) 0
Prohibits output when each bit
is set to ON.
W
⎯
#5 Output prohibition (Y20 to Y37) 0
Prohibits output when each bit
is set to ON.
W
⎯
#6 Output prohibition (Y40 to Y57) 0
Prohibits output when each bit
is set to ON.
W
⎯
#7 Executed bank No.
⎯⎯
W
⎯
#8
#8008
#9008 *1
Current angle (degrees)
⎯
×
1 value (1 degree),
×
2 value (0.5 degree)
R
⎯
#9
#8009
#9009 *1
Rotation angle (r/min)
⎯⎯
R
⎯
#10
#8010
#9010 *1
Output status (Y00 to Y17)
⎯
Monitors output status when
each bit is set to ON/OFF.
R
⎯
#11
#8011
#9011 *1
Output status (Y20 to Y37)
⎯
Monitors output status when
each bit is set to ON/OFF.
R
⎯
#12
#8012
#9012 *1
Output status (Y40 to Y57)
⎯
Monitors output status when
each bit is set to ON/OFF.
R
⎯
#13
Speed of automatic angle advance
S0 (r/min)
0
⎯
W, K D7146
#14
Angle advance quantity of
automatic angle advance S0
(degrees)
0
×
1 value (1 degree),
×
2 value (0.5 degree)
W, K D7147
#15
Speed of automatic angle advance
S1 (r/min)
0
⎯
W, K D7148
#16
Angle advance quantity of
automatic angle advance S1
(degrees)
0
×
1 value (1 degree),
×
2 value (0.5 degree)
W, K D7149