Basic Setting 6
6-8
FX
2N
-1RM-E-SET Programmable Cam Switch
When individual automatic angle advance function is used, addition of the crack of rotation speed
and angle advance quantity to buffer memory (BFM) is as follows.
BFM No.
Rotation speed
ON angle
advance quantity
OFF angle
advance quantity
Y0 S0
S1
S2
S3
S4
S5
S6
6376
6379
6382
6385
6388
6391
6394
6377
6380
6383
6386
6389
6392
6395
6378
6381
6384
6387
6390
6393
6396
Y1 S0
S1
S2
S3
S4
S5
S6
6397
6400
6403
6406
6409
6412
6415
6398
6401
6404
6407
6410
6413
6416
6399
6402
6405
6408
6411
6414
6417
Y2 S0
S1
S2
S3
S4
S5
S6
6418
6421
6424
6427
6430
6433
6436
6419
6422
6425
6428
6431
6434
6437
6420
6423
6426
6429
6432
6435
6438
Y3 S0
S1
S2
S3
S4
S5
S6
6439
6442
6445
6448
6451
6454
6457
6440
6443
6446
6449
6452
6455
6458
6441
6444
6447
6450
6453
6456
6459
• When the mode is selected 1
degree (360 degrees/
revolution), input equals
advance angle value.
When the mode is selected
0.5 degrees (720 degrees/
revolution), inputs equals
twice the advance angle
value. (input 10, advance
angle=5)
• The executed program
number can be used from
Caution on batch transfer of programs
When the batch transfer of the program is done with the personal computer and FX-
20P-E when the Individual automatic angle advance function is used, all the data of
the rotational speed, the turning ON angle, and the turning OFF angle is treated by
the twice value.