Program Operating Procedures 8
8-9
FX
2N
-1RM-E-SET Programmable Cam Switch
8.2.7 Write and modification of teaching
Treat the current position of the resolver as the set value.
Connect the resolver to the FX
2N
-1RM before turning on the power.
BANK
0
OUT
0
STEP
0
DEG
Blank*1
ON LED
Lit
OFF LED
Exting-
uished
< Key operation >
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
< Display >
*1 When a modification operation is performed,
the ON angle of the output Y00 already
registered is displayed.
0
TEACH
BANK GO
Read the program bank No. 0.
BANK
0
OUT
0
STEP
0
DEG ON LED OFF LED
Lit
The angle in the current position flashes on the
DEG .
The OFF LED is lit to indicate that the process
has proceeded to setting of the OFF angle of the
same step.
Start to set the ON angle of the
output Y00.
*2 When the [GO] key is pressed while modification
is performed, the OFF angle of the same step is
displayed.
When the [ON OFF] or [GO] key is pressed while
data is newly written or when the [ON OFF] key
is pressed while the existing data is modified, the
current angle flashes.
0OUT GO
Read the output Y00.
0STEP GO
Read the step No. 0.
Stop the resolver in
a position in which
it is to be rotated.
GO
ON
OFF
Stop the resolver in
a portion in which it
is to be rotated.
BANK
0
OUT
0
STEP
1
DEG
Blank*3
ON LED
Lit
OFF LED
Exting-
uished
*3 When a modification operation is performed,
the ON angle of the next step already
registered is displayed.
GO
Determine the OFF angle.
The ON/OFF set angle is
written to the built-in
EEPROM.
or
Determine the ON angle.
When data is newly written or
the [ON OFF] key is pressed,
the process proceeds to
setting of the OFF angle.
When the existing data is
modified, the contents of
modification are written to the
EEPROM when the [GO] key
is pressed.
# # #
*2
Exting-
uished